BPL’s first ECG machine was introduced in 1967 and now BPL has foray of devices from Single-Channel to 12-Channel ECG. Mastering excellence in Design & Manufacturing, BPL’s ECG machines have been a synonym for reliability.
Megamed provides 100% Genuine BPL ECG machines and Accessories
BPL Cardiart GenX1 Features
- Single-channel ECG recorder with 12-lead simultaneous acquisition
- Large character LCD display
- One-touch operation with soft silicone keys
- Auto, manual & rhythm modes
- Uses Glasgow ECG Interpretation algorithm
- Built-in rechargeable Li battery
- Optional: Real-time ECG data transfer to PC through USB
Product Specification
Specifications:
Model |
BPL Cardiart GenX1 |
Speciality |
Cardiology |
Power Supply |
100 to 240VAC; 50 / 60 Hz |
Power Consumption |
Less than 40VA |
Battery Capacity |
Auto Mode: 200 ECG?s in 1 channel format @25 mm/sec, 10mm/mV, 2.5 s,Normal trace & Interpretation – OFF |
Mains Protection (Fuse) |
T2A 250 V |
Battery Protection |
In built PCM Module |
Battery Charging Time |
Approximately 3 hours from total discharge (Unit off) |
ECG Acquisition |
12 bits; 1000 samples/sec/channel |
ADC Resolution |
2.55 ?V/LSB |
Input Dynamics |
DC offset: ± 300mV; AC Differential: ± 5mV in the pass band |
ECG Leads |
Standard 12 leads or Cabrera; Acquired 8 leads & Reconstructed 4 leads (Lead III, Lead aVR, Lead aVL, Lead aVF) |
Recording Sensitivity (Manual) |
2.5mm/mV,5mm/mV,10mm/mV, 20mm/mV ± 5% |
Recording Sensitivity (Auto) |
dependent on the signal strength, Optimizes automatically to 2.5mm/mV,5mm/mV,10mm/mV, 20mm/mV ± 5% |
Input Impedance |
Greater than 10 M? @ 10 Hz |
Frequency Response |
0.05 Hz to 150 Hz (-3dB) without Mains /Muscle and ADF Filters |
ECG Analysis & Interpretation |
Gender, Age & Race specific Advanced ECG Analysis & Interpretation – University of Glasgow in auto mode |
ECG Analysis Sampling Rate |
500 samples/second (sps) |
Mains interference/Muscle filter |
Linear phase digital 50Hz Notch filter with selectable 32Hz |
Anti-drift filter |
Selectable Digital 0.5Hz Anti Drift High pass linear phase filter |
Display |
Large, 16 x 2, Blue, Alphanumeric Display |
Keyboard |
Silicone Rubber keypad |
Paper Transport Speed |
5 mm/sec or 12.5 mm/sec or 25mm/sec or 50 mm/sec |
Print Formats: Manual: 1 Ch. Auto |
1 Ch, 1 Ch + 1 Rhythm with selectable print durations of 2.5 secs. / 5 secs. / 10 secs. |
PC Connectivity |
ECG transfer to PC through Rt-VIEW SOFTWARE(Optional) |
Operating Temperature |
+10 to +40°C |
Relative Humidity |
Upto 95% RH non-condensing |
Safety Classification |
Class I with internal power supply |
Degree Of Protection |
Type CF |
Dimension |
Approx. 300mm x 260mm x 80 mm (length x width x height) |
Weight |
Approx. 2 Kgs. |
|
Country Of Origin – India
Warranty – 1 Year
In the Box
BPL Single Channel ECG machine,GENX1 |
ECG Cable |
Bulb Electrode |
Clamp Electrode |
Gel Bottle |
ECG Paper Roll |
Battery |
Power Cable |
User Guide |
Reviews
There are no reviews yet.