BPL’s first ECG machine was introduced in 1967 and now BPL has foray of devices from Single-Channel to 12-Channel ECG. Mastering excellence in Design & Manufacturing, BPL’s ECG machines have been a synonym for reliability.
Megamed provides 100% Genuine BPL ECG machines and Accessories
BPL Cardiart GenX1 Features
- Single-channel ECG recorder with 12-lead simultaneous acquisition
- Large character LCD display
- One-touch operation with soft silicone keys
- Auto, manual & rhythm modes
- Uses Glasgow ECG Interpretation algorithm
- Built-in rechargeable Li battery
- Optional: Real-time ECG data transfer to PC through USB
Product Specification
Specifications: Model | BPL Cardiart GenX1 | Speciality | Cardiology | Power Supply | 100 to 240VAC; 50 / 60 Hz | Power Consumption | Less than 40VA | Battery Capacity | Auto Mode: 200 ECG?s in 1 channel format @25 mm/sec, 10mm/mV, 2.5 s,Normal trace & Interpretation – OFF | Mains Protection (Fuse) | T2A 250 V | Battery Protection | In built PCM Module | Battery Charging Time | Approximately 3 hours from total discharge (Unit off) | ECG Acquisition | 12 bits; 1000 samples/sec/channel | ADC Resolution | 2.55 ?V/LSB | Input Dynamics | DC offset: ± 300mV; AC Differential: ± 5mV in the pass band | ECG Leads | Standard 12 leads or Cabrera; Acquired 8 leads & Reconstructed 4 leads (Lead III, Lead aVR, Lead aVL, Lead aVF) | Recording Sensitivity (Manual) | 2.5mm/mV,5mm/mV,10mm/mV, 20mm/mV ± 5% | Recording Sensitivity (Auto) | dependent on the signal strength, Optimizes automatically to 2.5mm/mV,5mm/mV,10mm/mV, 20mm/mV ± 5% | Input Impedance | Greater than 10 M? @ 10 Hz | Frequency Response | 0.05 Hz to 150 Hz (-3dB) without Mains /Muscle and ADF Filters | ECG Analysis & Interpretation | Gender, Age & Race specific Advanced ECG Analysis & Interpretation – University of Glasgow in auto mode | ECG Analysis Sampling Rate | 500 samples/second (sps) | Mains interference/Muscle filter | Linear phase digital 50Hz Notch filter with selectable 32Hz | Anti-drift filter | Selectable Digital 0.5Hz Anti Drift High pass linear phase filter | Display | Large, 16 x 2, Blue, Alphanumeric Display | Keyboard | Silicone Rubber keypad | Paper Transport Speed | 5 mm/sec or 12.5 mm/sec or 25mm/sec or 50 mm/sec | Print Formats: Manual: 1 Ch. Auto | 1 Ch, 1 Ch + 1 Rhythm with selectable print durations of 2.5 secs. / 5 secs. / 10 secs. | PC Connectivity | ECG transfer to PC through Rt-VIEW SOFTWARE(Optional) | Operating Temperature | +10 to +40°C | Relative Humidity | Upto 95% RH non-condensing | Safety Classification | Class I with internal power supply | Degree Of Protection | Type CF | Dimension | Approx. 300mm x 260mm x 80 mm (length x width x height) | Weight | Approx. 2 Kgs. | |
Country Of Origin – India
Warranty – 1 Year
In the Box
BPL Single Channel ECG machine,GENX1 |
ECG Cable |
Bulb Electrode |
Clamp Electrode |
Gel Bottle |
ECG Paper Roll |
Battery |
Power Cable |
User Guide |
Reviews
There are no reviews yet.