Philips DFM100 Defibrillator is an affordable solution with the ability to adapt to changes in your clinical environment, resource needs, or critical care guidelines. It is a three in one Device which has AED, Defib and Monitoring System
Features
Improving cost-of-ownership
A complete package
Unique advantages
Philips DFM100 Defibrillator Specifications
-
Physical characteristics Filtration -
Rechargeable Lithium Ion battery; AC power using a protectively grounded outlet
-
-
General Approximate Dimensions -
23.5 cm (H) x 29 cm (W) x 20.5 cm (D); 9.25 in (H) x 11.4 in (W) x 8 in (D)
Approximate Weight (without battery) -
5.66 kg; 12.5 lbs
Standard Operator Position -
Within one meter (3 feet) of the device
Power -
Rechargeable Lithium Ion battery; AC power using a protectively grounded outlet
-
-
Display Size -
Approximately 7 in (17.8 cm) diagonal viewing area
Type -
Color TFT LCD
Resolution -
800 x 480 pixels (VGA) with 32 brightness levels per color
Wave Viewing Time -
6.5 sec ± 10%
Sweep Speed -
25 mm/s ± 10% nominal (stationary trace; sweeping erase bar) for ECG and SpO2; capnogram wave is 6.25 mm/s ± 10%
-
-
Philips DFM100 Defibrillator Shock Delivery -
Via multifunction electrode pads or paddles
Waveform -
Biphasic Truncated Exponential; waveform parameters adjusted as a function of patient impedance
Shock Series -
Configurable energy escalation in a series Leads Off Sensing and PCI
Charge time -
• Less than 5 seconds to the recommended adult energy level (150 Joules) with a new, fully-charged battery installed
-
• Less than 6 seconds to the selected energy level (up to 200 Joules) with a new, fully charged battery installed
-
• Less than 15 seconds to the selected energy level while connected to AC power only
-
• The device powers on in manual defibrillation mode ready to deliver shock in less than:
-
• 15 seconds with a new, fully-charged battery
-
• The device powers on in AED mode ready to deliver shock in less than:
-
• 24 seconds with a new, fully-charged battery even after 15 discharges of maximum energy
Sensing for Pads/Paddles -
Apply 500 nA rms (571 Hz); 200 uA rms (32 KHz)
Charge times -
• Less than 5 seconds to the recommended adult energy level (150 Joules) with a new, fully-charged battery installed • Less than 6 seconds to the selected energy level (up to 200 Joules) with a new, fully-charged battery installed • Less than 15 seconds to the selected energy level while connected to AC power only • The device powers on in manual defibrillation mode ready to deliver a shock in less than: • 15 seconds with a new, fully-charged battery • The device powers on in AED mode ready to deliver shock in less than: • 24 seconds with a new, fully-charged battery even after 15 discharges of maximum energy
Patient Impedance Range -
Minimum: 25 ohm (external defibrillation); 15 ohm (internal defibrillation) – Maximum: 250 ohm. Actual functional range may exceed these values
-
In The Box
- Philips DFM100 Defibrillator
- AC Power Cord
- Lithium Ion Battery
- Pads Cable with test Plug
- 1 Sleeve Paper Rolls
- 1 Package Electrodes
- Use Documentation and CD