Resmed Lumis 150 VPAP ST-A is a non-invasive ventilator with alarms. It is designed for non-dependent patients with respiratory insufficiency.
The ventilator features IntelligentAir, a collection of ResMed technologies that can tailor therapy to the patient’s breathing needs. IntelligentAir comprises iVAPS (intelligent Volume-Assured Pressure Support), a mode that automatically adapts to the patient’s changing needs; an intelligent Backup Rate (iBR)* that maximizes their opportunity to breathe spontaneously; and an optional AutoEPAP** feature to maintain upper airway patency.
A set of fixed and adjustable alarms for extra reassurance.
Fixed alarms include system events, such as power failures and system faults. Alarms that you can set are high leak, low minute ventilation, apnoea, non-vented mask, and low SpO2 (when an oximeter is connected).
iVAPS (intelligent volume assured pressure support)
iVAPS automatically learns each patient’s unique alveolar ventilation, sets appropriate targets, then provides smooth pressure support to suit.
Resmed Lumis 150 VPAP ST-A Features
- intelligent Backup Rate (iBR)* maximizes the patients’ opportunity to trigger the ventilator. Staying out of the way until needed, iBR adds backup breaths to comfortably bring patients back to target.
- Optional AutoEPAP** maintains upper airway patency by auto-adjusting the expiratory pressure in response to partial and full obstructions.
- Vsync provides excellent patient-ventilator synchrony, even in the presence of a significant leak.
- TiControl™ lets you set min and max limits on either side of the patient’s ideal inspiratory time to encourage spontaneous breathing.
- Trigger and cycle help you optimize settings according to the patient’s condition, using five trigger and cycle sensitivity levels.
- QuickNav for low-touch therapy adjustment. By simply double-clicking the home button on the device, you can toggle between the Settings and Monitoring screens to change and check settings quickly and easily.
- Climate Control Auto for automatic humidification. When used with a HumidAir™ heated humidifier and ClimateLineAir™ heated tube, Lumis delivers humidification automatically – no settings to change and no complicated menus to navigate.
- Ramp and Ramp Down. To help patients ease into a therapy session, the Ramp feature gradually and comfortably ramps the pressure up to their prescribed level; and to help ease them out of a therapy session, Ramp Down gradually reduces the EPAP and pressure support.
Technical Specifications
Modes | CPAP, S, T, ST with optional iBR, PAC, iVAPS with iBR and optional AutoEPAP |
Pressure Range | 2–30 cm H2O (2–25 hPa) in S, T, ST, PAC and iVAPS modes 4–20 cm H2O (4–20 hPa) in CPAP mode |
Sound Levels | 27 dBA with uncertainty of 2 dBA as measured according to ISO 80601-2-70:2015 (CPAP mode) |
Dimensions | 116 mm x 205 mm x 150 mm (Device only) 116 mm x 255 mm x 150 mm (Device with HumidAir heated humidifier) |
Weight | 1238 g (Device only) 1336 g (Device with HumidAir heated humidifier) |
Power Supply | Input range: 100–240V, 50–60Hz, 57VA (typical power consumption) 108VA (peak power consumption) |
Supplemental Oxygen | Supplemental oxygen Recommended maximum flow: 15 L/min (CPAP, S, T, ST, PAC); 4 L/min (iVAPS) |
Tubing | SlimLine™ and ClimateLineAir (15 mm); ClimateLineAir Oxy and Standard (19 mm) |
Air Outlet | 22 mm air outlet complies with ISO 5356-1:2004 |
I
in the Box
- Resmed Lumis 150 ST-A BIPAP Device
- Humidifier
- Climate Line Tubing Optional
- Power Adapter & Cable
- Tubing
- Travel Bag
- User Manuals